Cookie Settings

10 hp (7.5 kW) Air Compressor Motor, 208-230V, 1-3/8" Shaft

10 hp (7.5 kW) Air Compressor Motor, 208-230V, 1-3/8" Shaft
10 hp (7.5 kW) Air Compressor Motor, 208-230V, 1-3/8" Shaft
10 hp (7.5 kW) Air Compressor Motor, 208-230V, 1-3/8" Shaft
10 hp (7.5 kW) Air Compressor Motor, 208-230V, 1-3/8" Shaft
10 hp (7.5 kW) Air Compressor Motor, 208-230V, 1-3/8" Shaft
from
$1,212.25
Ex Tax: $1,212.25
  • Stock: In Stock
  • Model: SCJ009593
  • SKU: SCJ009593
Products Sold: 0
Product Views: 172
  • Description

10 hp (7.5 kW) Air Compressor Motor, 208-230V, 1-3/8" Shaft

Brief

Lower cost 10 hp air compressor motor shaft has a diameter of 1-3/8" inch and a length of 3.38 inch. 208-230VAC, 48-46A, 3600 rpm, 60Hz. It is IP23 single phase motor with double capacitance. High efficiency, low noise and low vibration.

Description

Buy 3600rpm 7.5kW air compressor motor at affordable price. 213/ 5T frame, steel housing, insulation class is F. It can be used for metal cutting, machine tools, water pumps, blowers, transportation machinery, agricultural machinery, etc.

Specification

ModelSCJ009593
Power10 HP (7.5 kW)
Speed3600 rpm
Current48-46 A
Voltage208-230 V
Protector×
Frame213/ 5T
Shaft diameter1-3/8"
Shaft length3.38"
Capacitance2
ENCODP
Frequency60Hz
IP23
INSF
ROTCW/ CCW
Housing materialSteel plate
Packing size60*38*42cm
Weight46kg

Dimention (Unit: inch)

10 hp (7.5 kW) Air Compressor Motor, 208-230V, 1-3/8" Shaft

Details

10 hp (7.5 kW) Air Compressor Motor, 208-230V, 1-3/8" Shaft

Tips: Air compressor motor troubleshooting - the motor current is too high

  1. The air compressor motor temperature controller is faulty, and the temperature controller needs to be replaced.
  2. The overload protector is faulty, and the overload protector needs to be replaced.
  3. The air inlet is blocked and needs cleaning and maintenance.
  4. The drive belt tension is too tight. Loosen the transmission belt, the normal tension of the air compressor is 0.8-1.0cm downward pressure.
  5. The air filter is blocked and needs to be replaced (when the vacuum value is greater than 5psi).
  6. The starter contacts are in poor contact, and the starter contacts need to be maintained.
  7. The oil and gas separator is blocked, and the oil and gas separator needs to be replaced (when the pressure difference is greater than 0.8-1kg).
  8. If the motor bearing is not oiled, it is necessary to add grease to the motor bearing.
  9. If the ambient temperature is too high, it is necessary to install ducted exhaust equipment.
  10. Three-phase voltage is unstable, lack of phase, and voltage is too low (less than 10%). It is recommended to improve the power system.
  11. The motor bearing is damaged, and the motor needs to be removed for insulation strengthening.
  12. The motor insulation is poor, and the motor bearings need to be replaced.
  13. The motor wiring is loose, and the motor wiring needs to be re-locked.
  • Reviews

Write a review

Note: HTML is not translated!
Rating
Bad Good
Captcha
refresh-code