60 MHz Handheld Oscilloscope 500 MSa/s Single Channel 1pc

60 MHz Handheld Oscilloscope 500 MSa/s Single Channel 1pc
60 MHz Handheld Oscilloscope 500 MSa/s Single Channel 1pc
60 MHz Handheld Oscilloscope 500 MSa/s Single Channel 1pc
60 MHz Handheld Oscilloscope 500 MSa/s Single Channel 1pc
60 MHz Handheld Oscilloscope 500 MSa/s Single Channel 1pc
from
$554.13
Ex Tax: $554.13
  • Stock: In Stock
  • Model: SCJ009643
  • SKU: SCJ009643
  • UPC: 315972715914
Products Sold: 0
Product Views: 439
  • Description

60 MHz Handheld Oscilloscope 500 MSa/s Single Channel 1pc

Brief

The 3-in-1 oscilloscope and multimeter offer a bandwidth of 60 MHz, sample rates of 500 MSa/s, and record lengths of 24k points. Digital oscilloscope has the advantages of small in size, lightweight, multifunction and long service life.

Description

Lower-cost single-channel portable oscilloscope with 500 MSa/s sample rates, 8 bits, and 6 kinds of automatic measurement functions. The single-channel oscilloscope can quickly and accurately detect the faults of the circuit under test and can serve as an assistant, and will provide a great convenience for you at work.

Specification

Performance Characteristics

ModelSCJ009643
Bandwidth60 MHz
ChannelSingle channel
Sample rate500 MSa/s
Horizontal Scale (s/div)5ns/div~100s/div, step by 1~2.5~5
Record length24K points
Display3.7" color TFT display (640 * 480 pixels)
Waveform refresh rate10000 wfrms/s
Input couplingDC, AC, Ground
Input impedance1 MΩ±2%, in parallel with 18 pF±5 pF
Probe attenuation1X,10X,100X,1000X
Max. input voltage400V (PK - PK) (DC + AC, PK - PK, 1MΩ input impedance, probe attenuation 10 : 1), CAT II
Bandwidth limit(typical)20MHz / Full bandwidth
Sampling rate range5ns/div ~ 500s/div, step by 1 – 2 - 5
DC Accuracy (average)average >16: ±(5% reading + 0.05div) for △V
Vertical Sensitivity5mV/div~5V/div (at input)
Rise time (at input, Typical)≤ 17.5ns
Trigger typeEdge and Video
Trigger modelAuto, Normal, Single
Trigger level range±6 div from the screen center
Automatic measurementVpp, Vavg, Vrms, Freq, Period, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot,
Preshoot, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay A→B , Delay A→B
Cursor measurementΔV, ΔT, ΔT&ΔV between cursors,auto cursor
Communication interfaceUSB Type-C
Acquisition ModeSample, Peak Detect, and Average
Interpolationsin (x) / x
Vertical Resolution (A/D)8 bits
Waveform Storage4 waveforms
Communication InterfaceMini-USB,mini-RS232
Power Supply100V-240V AC, 50/60Hz

Digital Multimeter Specification

Full-Scale Reading3 3/4 digits (max 4000-count)
Diode0V-1.5V
Input Impedance10 MΩ
On/ Off Test< 50 (± 30) beeping
VoltageVDC: 400mV, 4V, 40V, 400V, 1000V : ±(1% ± 1 digit); max input: DC 1000V
VAC: 4V, 40V, 400V: ±(1% ± 3 digits), 750V: ±(2% ± 3 digits); Frequency: 40Hz - 400Hz;
Max input: AC 750V (virtual value)
CurrentDC: 40mA, 400mA : ±(1.5% ± 1 digit), 10A: ±(3% ± 3 digits)
AC: 40mA: ±(1.5% ± 3 digits), 400mA: ±(2% ± 1 digit), 10A : ±(5% ± 3 digits)
Impedance400Ω: ±(1% ± 3 digits), 40ΚΩ - 4ΜΩ: ±(1% ± 1 digit), 40MΩ: ±(1.5% ± 3 digits)
Capacitance51.2nF - 100uF: ±(3% ± 3 digits)

Accessories

  • Power cord
  • CD rom
  • USB cable
  • Probe
  • Probe Adjust
  • Multimeter lead
  • Adapter
  • User manual
  • 5V, 1KHz Output
  • Capacitance Ext Module
  • Soft Bag
  • Metal Case (optional)

Dimension (mm)

60 MHz Handheld Oscilloscope, 500 MSa/s, Single Channel

Tips: Tips for using a handheld oscilloscope

  • Thermal electronic instruments generally need to avoid frequent startup and shutdown, and the same is true for oscilloscopes.
  • If you find that the waveform is disturbed by the outside world, you can ground the oscilloscope shell.
  • The voltage of "Y input" should not be too high, so as not to damage the instrument, and it should not exceed 400V at the maximum attenuation. When the "Y input" wire is suspended in the air, interference waveforms will appear due to external electromagnetic interference, which should be avoided.
  • Before shutting down, turn the brightness adjustment knob counterclockwise to the bottom to minimize the brightness, and then turn off the power switch. Analog oscilloscope.
  • When observing and adjusting the bright spot on the screen, the brightness of the bright spot should be moderate and not too bright.
  • Reviews

Write a review

Note: HTML is not translated!
Rating
Bad Good
Captcha
refresh-code
Brief Two channel digital storage oscilloscope with 70 MHz bandwidth and 2 GSa/s sample rate which is designed and produced by SOCOJE. Up to 256 level..
from
$1,348.56
Ex Tax:$1,348.56
Add to Cart
Brief High sensitivity handheld oscilloscope with 2 channels, 70 MHz bandwidth, 250 MSa/s sample rate, 8K record length, 10,000 wfrms/s waveform refre..
from
$322.38
Ex Tax:$322.38
Add to Cart
100 MHz Socoje Digital Oscilloscope 2/4 Channels 4 GSa/s 1 setBrief 100 MHz digital oscilloscope from uses UltraVision innovative technology which com..
from
$2,568.56
Ex Tax:$2,568.56
Add to Cart
60 MHz PC Based Oscilloscope Dual Channel 1 GSa/s 1pcBrief high-accuracy PC-based oscilloscope with 2-channel, 60 MHz bandwidth, 1 GSa/s sampling rate..
from
$592.22
Ex Tax:$592.22
Add to Cart
Brief SOCOJE offers a digital oscilloscope which has 70 MHz bandwidth, 4 analog channels, 1 GSa/s maximum real-time sample rate, and 40 Mpts maximum m..
from
$1,223.17
Ex Tax:$1,223.17
Add to Cart