10 hp (7.5 kW) Air Compressor Motor 208-230V 1-3/8 Shaft
from
$1,212.25
Ex Tax: $1,212.25
- Stock: In Stock
- Model: SCJ009593
- SKU: SCJ009593
Products Sold: 0
Product Views: 219
Ask a Question About This Product
- Description
10 hp (7.5 kW) Air Compressor Motor 208-230V 1-3/8 Shaft
Brief
Lower cost 10 hp air compressor motor shaft has a diameter of 1-3/8 inch and a length of 3.38 inch. 208-230VAC, 48-46A, 3600 rpm, 60Hz. It is IP23 single phase motor with double capacitance. High efficiency, low noise and low vibration.
Description
Buy 3600rpm 7.5kW air compressor motor at affordable price. 213/ 5T frame, steel housing, insulation class is F. It can be used for metal cutting, machine tools, water pumps, blowers, transportation machinery, agricultural machinery, etc.
Specification
Model | SCJ009593 |
Power | 10 HP (7.5 kW) |
Speed | 3600 rpm |
Current | 48-46 A |
Voltage | 208-230 V |
Protector | × |
Frame | 213/ 5T |
Shaft diameter | 1-3/8 |
Shaft length | 3.38 |
Capacitance | 2 |
ENC | ODP |
Frequency | 60Hz |
IP | 23 |
INS | F |
ROT | CW/ CCW |
Housing material | Steel plate |
Packing size | 60*38*42cm |
Weight | 46kg |
Dimention (Unit: inch)
Details
Tips: Air compressor motor troubleshooting - the motor current is too high
- The air compressor motor temperature controller is faulty, and the temperature controller needs to be replaced.
- The overload protector is faulty, and the overload protector needs to be replaced.
- The air inlet is blocked and needs cleaning and maintenance.
- The drive belt tension is too tight. Loosen the transmission belt, the normal tension of the air compressor is 0.8-1.0cm downward pressure.
- The air filter is blocked and needs to be replaced (when the vacuum value is greater than 5psi).
- The starter contacts are in poor contact, and the starter contacts need to be maintained.
- The oil and gas separator is blocked, and the oil and gas separator needs to be replaced (when the pressure difference is greater than 0.8-1kg).
- If the motor bearing is not oiled, it is necessary to add grease to the motor bearing.
- If the ambient temperature is too high, it is necessary to install ducted exhaust equipment.
- Three-phase voltage is unstable, lack of phase, and voltage is too low (less than 10%). It is recommended to improve the power system.
- The motor bearing is damaged, and the motor needs to be removed for insulation strengthening.
- The motor insulation is poor, and the motor bearings need to be replaced.
- The motor wiring is loose, and the motor wiring needs to be re-locked.