Cookie Settings

100 MHz Socoje Handheld Oscilloscope, 1 GSa/s, Single Channel 1 set

100 MHz Socoje Handheld Oscilloscope, 1 GSa/s, Single Channel 1 set
100 MHz Socoje Handheld Oscilloscope, 1 GSa/s, Single Channel 1 set
100 MHz Socoje Handheld Oscilloscope, 1 GSa/s, Single Channel 1 set
100 MHz Socoje Handheld Oscilloscope, 1 GSa/s, Single Channel 1 set
100 MHz Socoje Handheld Oscilloscope, 1 GSa/s, Single Channel 1 set
from
$649.37
Ex Tax: $649.37
  • Stock: In Stock
  • Model: SCJ009636
  • SKU: SCJ009636
  • UPC: 315972716584
Products Sold: 0
Product Views: 455
  • Description

100 MHz Socoje Handheld Oscilloscope, 1 GSa/s, Single Channel 1 set

Brief

The single channel 100 MHz handheld oscilloscope provides 1 GSa/s real-time sample rate and a waveform acquisition rate of 4 waveforms per second. The digital oscilloscope is ideal for communications, defense, aerospace and industrial electronics.

Description

This compact portable oscilloscope is a high-quality single-channel, 100 MHz bandwidth digital oscilloscope which ensures a more rapid capturing of instantaneous or abnormal signals for accelerating signal analysis and fault tracing. The high-quality 100 MHz oscilloscope is a portable tool for waveform measurement, features an auto-scale function, USB data transmission, and waveform record and replay. 

Specification

Performance Characteristics

ModelSCJ009636
Bandwidth100 MHz
ChannelSingle channel
Sample rate1 GSa/s
Horizontal Scale (s/div)5ns/div~100s/div, step by 1~2.5~5
Record length24K points
Display3.7" color TFT display (640 * 480 pixels)
Waveform refresh rate10000 wfrms/s
Input couplingDC, AC, Ground
Input impedance1 MΩ±2%, in parallel with 18 pF±5 pF
Probe attenuation1X,10X,100X,1000X
Max. input voltage400V (PK - PK) (DC + AC, PK - PK, 1MΩ input impedance, probe attenuation 10 : 1), CAT II
Bandwidth limit(typical)20MHz / Full bandwidth
Sampling rate range5ns/div ~ 500s/div, step by 1 – 2 - 5
DC Accuracy (average)average >16: ±(5% reading + 0.05div) for △V
Vertical Sensitivity5mV/div~5V/div (at input)
Rise time (at input, Typical)≤ 17.5ns
Trigger typeEdge and Video
Trigger modelAuto, Normal, Single
Trigger level range±6 div from the screen center
Automatic measurementVpp, Vavg, Vrms, Freq, Period, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot,
Preshoot, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay A→B , Delay A→B
Cursor measurementΔV, ΔT, ΔT&ΔV between cursors,auto cursor
Communication interfaceUSB Type-C
Acquisition ModeSample, Peak Detect, and Average
Interpolationsin (x) / x
Vertical Resolution (A/D)8 bits
Waveform Storage4 waveforms
Communication InterfaceMini-USB,mini-RS232
Power Supply100V-240V AC, 50/60Hz

Digital Multimeter Specification

Full-Scale Reading3 3/4 digits (max 4000-count)
Diode0V-1.5V
Input Impedance10 MΩ
On/ Off Test< 50 (± 30) beeping
VoltageVDC: 400mV, 4V, 40V, 400V, 1000V : ±(1% ± 1 digit); max input: DC 1000V
VAC: 4V, 40V, 400V: ±(1% ± 3 digits), 750V: ±(2% ± 3 digits); Frequency: 40Hz - 400Hz;
Max input: AC 750V (virtual value)
CurrentDC: 40mA, 400mA : ±(1.5% ± 1 digit), 10A: ±(3% ± 3 digits)
AC: 40mA: ±(1.5% ± 3 digits), 400mA: ±(2% ± 1 digit), 10A : ±(5% ± 3 digits)
Impedance400Ω: ±(1% ± 3 digits), 40ΚΩ - 4ΜΩ: ±(1% ± 1 digit), 40MΩ: ±(1.5% ± 3 digits)
Capacitance51.2nF - 100uF: ±(3% ± 3 digits)

Accessories

  • Power cord
  • CD rom
  • USB cable
  • Probe
  • Probe Adjust
  • Multimeter lead
  • Adapter
  • User manual
  • 5V, 1KHz Output
  • Capacitance Ext Module
  • Soft Bag
  • Metal Case (optional)

Dimension (mm)

100 MHz Handheld Oscilloscope, 1 GSa/s, Single Channel

Tips: How to use a handheld oscilloscope?

  • Select and set the probe:  First, according to the need to choose a suitable probe, for most of the measured signal, you buy the instrument that comes with a simple passive probe that can be used. Next, set the attenuation of the probe, which is generally used is 10X, it is the best choice for many occasions, if you want to measure the amplitude of the smaller signal, you can set it in the 1X file.
  • Connect the probe, and open the oscilloscope: Connect the probe to the first channel of the oscilloscope, and turn on the oscilloscope switch to start running, you can see the oscilloscope screen with squares, scales, and a waveform consisting of a horizontal line with faint noise fluctuations.
  • Calibrating the probe:  Oscilloscopes generally provide an internally generated, highly reliable, fixed frequency and amplitude square wave test signal for calibration on the lower right side of the panel, with two separate connections - one to output the calibration signal and one to connect to system ground. Connect the probe's ground clamp to the ground side of this test signal and the oscilloscope's probe to the test signal's output.
  • Reviews

Write a review

Note: HTML is not translated!
Rating
Bad Good
Captcha
refresh-code
100 MHz Socoje Handheld Oscilloscope, 500 MSa/s, 2 Channels 1pcBrief handheld oscilloscope with brandwidth 100MHz for sale online, 500 MSa/s sampling ..
from
$401.75
Ex Tax:$401.75
Add to Cart
20 MHz Digital Oscilloscope, 2 Channels, 100 MSa/sBrief Dual channel digital oscilloscope with 20 MHz bandwidth, max. real-time sample rate up to 100 ..
from
$514.60
Ex Tax:$514.60
Add to Cart
20 MHz Handheld Oscilloscope, 500 MSa/s, Single ChannelBrief Single channel handheld oscilloscope with for sale. The digital oscilloscope with 20 MHz ..
from
$458.89
Ex Tax:$458.89
Add to Cart
200 MHz Handheld Oscilloscope, 1 GSa/s, 2 ChannelsBrief High accuracy 2-channel handheld oscilloscope with 200 MHz bandwidth, 1 GSa/s sample rate, 8K ..
from
$592.22
Ex Tax:$592.22
Add to Cart
25 MHz Socoje PC Based Oscilloscope, Dual Channel, 100 MSa/s 1pcBrief Lower cost PC-based oscilloscope is a high-accuracy dual-channel digital oscillo..
from
$750.95
Ex Tax:$750.95
Add to Cart