- Stock: In Stock
- Model: SCJ009499
- SKU: SCJ009499
Available Options
Ask a Question About This Product
- Description
3 hp NEMA AC Induction Motor, Three Phase 230/460V, ODP/TEFC
Brief
Description
This dependable and powerful three phase SOCOJE AC electric motor with lower cost, 3 hp output power, ODP/ TEFC enclosure, class F insulation class, providing max speed to 3450rpm, designed for pumps, fans, compressors and other general purpose applications where contaminants are minimal.
3 hp 3 phase AC Induction Motor Specification
Basics | Model | SCJ009499 | SOCOJERT32T11 |
Enclosure | ODP | TEFC | |
Type | General Purpose Asynchronous Motor | ||
Item Weight | 83 Ibs | ||
Motor Length | 16.5 inch | 14.6 inch | |
Frame | 182TC Frame | 145TC Frame | |
Design | NEMA Design B | ||
Certification | CE, UL | ||
Motor Material | Roll Steel | ||
Technical Parameters | Service Factor | 1.15 | 1.25 |
Horsepower | 3 hp | ||
Rated Frequency | 60 Hz | ||
Phase | Three Phase | ||
Pole | 2 pole | ||
Voltage | 230/460V AC | ||
Full Load Amps | 7.26/3.63A | 7.17/3.59A | |
Speed | 3450 RPM | ||
Efficiency | 86.5% | ||
Duty | Continuous | ||
Isulation Class | Class F | ||
Protection Class | IP54/ IP55 | ||
Mounting Method | C Face, Footed | ||
Environment | Ambient temperature | -15℃≤θ≤40℃ | |
Altitude | Altitude should be lower than 1000 meters above sea level |
3 hp 3 phase AC Induction Motor Dimension
Unit: inch
Frame Size | AB | BA | Max A | Max B | Max BB | Max BD | C | D | E | 2F | H | N-W | O | P | R | S | U | Min ES | Min AA | AH | BF | BC | AJ | AK | Min V |
145TC | 5.6 | 2.75 | 7 | 6.18 | 0.16 | 6.5 | 14.6 | 3.5 | 2.75 | 4 | 0.34 | 2.25 | 6.7 | 7.08 | 0.771 | 0.188 | 0.875 | 1.41 | 3/4 | 2.12 | 1/2-13 | +0.12 | 5.875 | 4.5 | 2 |
182TC | 7.2 | 3.5 | 8.5 | 6.5 | 0.25 | 9 | 16.5 | 4.5 | 3.75 | 4.5 | 0.41 | 2.75 | 9.25 | 9.65 | 0.986 | 0.25 | 1.125 | 1.78 | 3/4 | 2.62 | 1/2-13 | +0.12 | 7.25 | 8.5 | 2.5 |
NEMA AC Induction Motor Connection Diagram
Details
Tips: Why The induction motor frame is electrified?
The reason for the motor frame with electricity may be that the motor shell is not connected with the ground or has been damaged. If the grounding equipment is damaged, the motor winding is affected with the damp and the insulation is aged. As a result, the current may leak out due to poor insulation. Or the outgoing line has been connected with the motor enclosure.
For this problem, first of all, check if the motor grounding equipment is perfect and reconnect it with the ground. If the motor get humid, it needs to be dried. The winding with seriously aged insulation should be exchanged.
- Reviews