Cookie Settings

Nema 23 Stepper Motor, 4.2A, 1.8 degree, 2 phase 4 wires

Nema 23 Stepper Motor, 4.2A, 1.8 degree, 2 phase 4 wires
Nema 23 Stepper Motor, 4.2A, 1.8 degree, 2 phase 4 wires
from
$88.08
Ex Tax: $88.08
  • Stock: In Stock
  • Model: SCJ009438
  • SKU: SCJ009438
Products Sold: 0
Product Views: 410

Available Options

  • Description

Nema 23 Stepper Motor, 4.2A, 1.8 degree, 2 phase 4 wires

Brief

Favorable price Nema 23 stepper motor, 3.0Nm holding torque, 4.2A phase current, 1.8 deg. step angle(200 steps/revolution), high quality and manufacturer direct sale.

Description

Nema 23 Stepper motor, 3.0Nm in 111mm, 1.8 degree.

Specification

Electrical SpecificationModelSOCOJE57STH111-4004
Matched Driver ModelSCJ009438(Click it to see more info)
Step Angle1.8°
Holding Torque3.0Nm
Rated Current/phase4.2A
Phase Resistance0.9Ω
Inductance3.8mH
Rotor Inertia800g-cm2
Physical SpecificationFrame Size57 x 57mm
Length111mm
Shaft DiameterΦ6.35mm
Shaft Length19mm
Motor Leads4
Weight1.4kg
Technical ParametersStep Angle Accuracy±5% (full step, no load)
Resistance Accuracy±10%
Inductance Accuracy±20%
Temperature Rise80℃ Max. (rated current, 2 phase on)
Ambient Temperature-20℃~+50℃
Insulation Resistance100MΩ Min. 500VDC
Dielectric Strength500V AC for one minute
Shaft Radial Play0.02Max. 450g
Shaft Axial Play0.08Max. 450g
Quality AssuranceWarranty Period12 months
CertificateCE, ROHs, ISO/SGS9001

Dimensions: (Unit=mm)

Nema 23 Stepper Motor, 4.2A, 1.8 degree, 2 phase 4 wiresL Max=111mm

Wiring Diagram

Nema 23 Stepper Motor, 4.2A, 1.8 degree, 2 phase 4 wiresTips: Solutions to interference of stepper motor

  1. Install power filter to reduce the contamination of AC power.
  2. Based on the principle of “single-point-earthing”, connect all the following earthing lines or something else to the earthing rod on wall of chassis, including grounding wire of power filter and stepper driver PE (the baseboard of driver and chassis should be insulated.), control pulse and direction pulse DIR-outgoing lines of short circuit, motor earthing line, cable protecting cover between driver and motor and shielded wire of driver, and good contact should be realized.
  3. Lengthen the distance between control line, power line (L and N) and motor drive line (U, V and W) to avoid crossing. For example, when dealing with the driver installation site of two drivers of the same chassis in the double-shaft system, put the nameplate of one driver forward and that of the other backward, and shorten the leads as far as possible when making structural arrangement.
  4. Reduce the external interference in power line with the shielded line or the interference of power line in external world.
  • Reviews

Write a review

Note: HTML is not translated!
Rating
Bad Good
Captcha
refresh-code